Description | Part No. | Length | NYA/ NLA** |
CAD | Connector 1st EB+ | Connector 2nd |
---|---|---|---|---|---|---|
![]()
|
814029001 | A = 1 m
B = 1 m |
![]() |
Power B,
black, 7 pole |
DIN 72585 connector (A) Sensor connector (B) |
|
814029011 | A = 6 m
B = 5 m |
|||||
814029021 | A = 6 m
B = 1 m |
**NYA = Not yet available, NLA = Not longer available
General
- Backup power and control input (Super AUX) cable connecting into lighting system
- Default cable in case where e.g. a lift axle or a steer axle is installed and traction support from cab and/or locking during reversing is needed, cable supports additional connection of a trailer mounted switch by sensor connector
- Super AUX control inputs (3) can be linked by software setup to all AUX functions, refer to DIAG+ AUX Setup
- Notice also Super AUX sample installations in the AUX schematic database
- Lightning system must provide corresponding connector.
- Conforms to IP67 (BS EN 60529) when mated with EB+ ECU Super AUX port (GEN2 / GEN3 )
- Cable material: PVC, ADR approved
- ECU connector: black
- Bayonet connector: DIN 72585, ISO 15170-B1-4.1-Sn/K1
- Switch connector: Male sensor
- Operating voltage: 12 - 24V
- Operating temperature: -40°C to +70°C
Connector (Top View)

Cable
ECU Connector Socket |
DIN Connector Pin |
Sensor Connector Pin |
Function | mm² |
---|---|---|---|---|
1 | - | - | Not used | |
2 | 1 | - | B + / Stop light Input | 1.5 |
3 | - | 2 | 24V Output, low current | 1.0 |
4 | - | 1 | Super AUX C Input | 1.0 |
5 | 4 | - | Super AUX B Input | 1.5 |
6 | 2 | - | B - Input | 1.5 |
7 | 3 | - | Super AUX A Input | 1.5 |