3 Sensors / 1 Offset / external lamps

General

  • Layout shows the recommended US-sensor position
  • yellow and green dots indicate sensors connected to the corresponding two system channels
  • an offset can be set per channel not per sensor
  • Default offset = 0 cm

SD2_3S_1Off_No_Lamp.png

 

Special

  • DIAG+ offset setting for green == yellow
  • Because of equal offset settings the centre sensor can be linked to both channels alternatively. System will detect the presence automatically.
  • external connection of LED outline marker lamps over cable (2)
 

Components

Item Qty. Description Part No. Notes
1 1 EB+ Soft Docking ECU 364 608 001  
2 1 Supply and brake cable 364 610 001 green connector onECU
5 1 Sensor and audio beeper cable 364 605 001 brown connector on ECU
6 1 Audio beeper 364 616 001  
7 3 Ultrasonic sensor 364 614 001  
8-1 1 Sensor splitter cable 364 607 001 0.5 m / 0.5 m / 0.5 m