5 Sensors / 2 Offsets

General

  • Layout shows the recommended US-sensor position
  • yellow and green dots indicate sensors connected to the corresponding two system channels
  • an offset can be set per channel not per sensor
  • Default offset = 0 cm
SD2_5S_2Off.png
 

Special

  • DIAG+ offset setting for green <> yellow
  • because of the mounting position the lower sensors share the same offset, the top level sensors offset is different
  • therefore the sensors per level must be linked to the same channel
  • if you choose green or yellow makes no difference, it's only important that the channel offset matches the mounting position
  • 1x extension cable required to reach top level
  • 1x extension cables required to connect top level sensor

 

Components

Item Qty. Description Part No. Notes
1 1 EB+ Soft Docking  ECU 364 608 001  
2 1 Outline marker lamp and brake cable 364 606 001 green connector on ECU
3 1 LED outline marker lamp (left) 364 617 001  
4 1 LED outline marker lamp (right) 364 617 011  
5 1 Sensor and audio beeper cable 364 605 001 brown connector on ECU
6 1 Audio  beeper 364 616 001  
7 5 Ultrasonic sensor 364 614 001  
8-1 2 Sensor splitter cable 364 607 001 0.5 m / 0.5 m / 0.5 m
8-4 1 Sensor splitter cable 364 607 001 0.5 m / 0.5 m / 0.5 m
2 Sensor extension cable 3m 364 622 011