U-ABS ECU needs power supply and input signals, controls ABS solenoids and auxiliaries, can be extended with devices like TPMS or Infocentre as well as being checked with diagnostic tool DIAG+.
This exhaustive list gives you the possibility to find the right cable quickly, with additional information like length, availability, diagnostic and more !
Find the part you need
ISO7638 - 24N - Solenoid - Wheel sensor - Auxiliary - Diagnostic
- ISO 7638 socket for semi trailer
- U-ABS Power-A plug
- 5 pins
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
364 510 001 | 12 | ![]() |
364 510 021 | 15 |
ISO7638 to Power-A - Trailer
- ISO 7638 plug for trailer
- U-ABS Power-A plug
- 5 pins
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
364 594 011 | 16 | ![]() |
364 594 021 | 12,5 |
ISO7638 Aftermarket to Power-A
- ISO 7638 Modular ABS socket (Framatome)
- U-ABS Power-A plug
- 5 pins
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
364 574 001 | 0.7 | ![]() |
Power-A to Power-A
- U-ABS Power-A plug (2x)
- 5 pins
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
364 591 001 | 2 | ![]() |
364 591 011 | 4 |
Power-A splitter
- U-ABS Power-A socket (3x)
- For multiple U-ABS ECU installation
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
364 590 001 | - | ![]() |
- Open end
- Power-B plug
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
364 509 001 | 12 | ![]() |
364 509 021 | 15 |
24N DIN to Power B
- DIN socket
- Power-B plug
- Part number 364 588 0** - Inactive
- Find technical drawing here
- All variants fullfil ADR specifications
- More information and diagnostic
24N Aftermarket to Power-B
- Framatome plug
- Power-B plug
- For 24N Modular ABS socket
- Part number 364 575 001 - Inactive
- Find technical drawing here
- All variants fullfil ADR specifications
- More information and diagnostic
- DIN plug for U-ABS solenoïd
- Aux plug
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
364 572 051 For 3rd Modulator |
10 | ![]() |
364 572 061 For 3rd Modulator |
14 |
- Wheel speed sensor plug
- ECU wheel speed sensor plug
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 004 421 | 2 | ![]() |
814 004 401 | 3 | |
814 004 471 | 4 | |
814 004 411 | 6 | |
814 004 451 | 8 | |
814 004 431 | 10 | |
814 004 461 | 12 | |
814 004 441 | 14 |
- Open end
- Aux plug
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 001 342 | 1 |
|
814 001 322 | 2 | |
814 001 332 | 4 | |
814 001 302 | 7 | |
814 001 372 | 10 | |
814 001 352 | 12 | |
814 001 312 | 18 |
DIN to Aux
- DIN 72585 plug
- Aux plug
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 012 221 | 1 |
|
814 012 231 | 2 | |
814 012 251 | 3 | |
814 012 261 | 4 | |
814 012 241 | 5 | |
814 012 201 | 7 | |
814 012 271 | 10 | |
814 012 211 | 18 |
DIN Aux splitter
- DIN 72585 plug (2x)
- DIN 72585 socket
- For auxiliary outputs only
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 027 001 | 0.5 | ![]() |
Aux to Aux
- AUX plug (2x)
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 032 001 | 1 | ![]() |
Aux splitter
- Aux socket (3x)
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 039 101 | 0.5 | ![]() |
- DIAGN/CAN plug
- SOV Framatome plug
- For EB+ Infocentre, when used as workshop diagnostic tool (compatible with U-ABS)
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 025 001 | 1 | ![]() |
SOV socket to DIAGN/CAN
- SOV Framatome socket
- DIAGN/CAN plug
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 030 011 | 2.5 | ![]() |
814 030 021 | 5 | |
814 030 001 | 6.5 | |
814 030 031 | 15 |
PC interface to SOV
- SUB-D 25 connector
- SOV Framatome plug
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 011 001 | 6.5 |
|
814 011 011 | 15 |
DIN to DIAGN/CAN
- DIN 72585 plug
- DIAGN/CAN plug
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 033 001 | 1 | ![]() |
814 033 011 | 12 |
PC interface to DIAGN/CAN
- SUB-D 25 pin connector
- DIAGN/CAN plug
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 036 001 | 6.5 | ![]() |
814 036 011 | 15 | |
814 036 021 | 20 |
- DIAGN/CAN plug (2x)
- for EB+ Infocentre connection (U-ABS compatible)
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 037 011 | 0.5 | ![]() |
814 037 051 | 1 | |
814 037 001 | 6.5 | |
814 037 021 | 8 |
DIAGN/CAN splitter
- DIAGN/CAN socket (3x)
- May need an additionnal DIAGN/CAN to DIAGN/CAN cable
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 038 001 | 0.5 | ![]() |
DIAGN/CAN splitter (with plug)
- DIAGN/CAN plug
- DIAGN/CAN socket (2x)
- No additional cable needed
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 038 101 | 0.5 | ![]() |
DIAGN/CAN to TPMS RCU
- DIAGN/CAN plug
- FCI plug
- For TPMS Receiver Control Unit (RCU)
- Variants available with or without CAN termination
- For applications with 2 TPMS RCUs, each one needs its own identifier (RCU2 / RCU3)
- Part number 814 040 1** - Inactive
- Find technical drawing here (only 814 040 1**)
- Part number 814 040 2** - Inactive
- Find technical drawing here (only 814 040 2**)
- All variants fullfil ADR specifications
- More information and diagnostic
Part number | Length (m) | Technical drawing |
---|---|---|
814 040 001 Rear unterminated - RCU3 |
1.2 | ![]() |